Tensile strength results​

After conducting the experimental procedures the following results were observed:

 

  • The product with the highest 28 day tensile strength was the CM3 with 2.5 MPa.

 

  • The product with the lowest 28 day tensile strength was the PM with 1.8 MPa.

 

  • It was noted that there was a 40% difference in tensile strength between the strongest and weakest product. 

 

  • CM2 had the highest strength gain, achieving 70% of its 28 day strength after 1 day.

 

  • Factors affecting results include; ammount of water added, product composition and method of loading.

 

 

 

 

 